Patients had invasive mechanical ventilation; vasoactive agent wasn’t used or had been evacuate | 是/Yes |
sinus rhythm | 是/Yes |
existing fluid infusion test contraindication (acute coronary syndrome, cardiogenic shock and evidence showing overload fluid) | 否/No |
being obvious right ventricular dysfunction, right heart failure and tricuspid regurgitation | 否/No |
being younger than 18 years old | 否/No |
being gestation | 否/No |
being intra-abdominal hypertension, bladder pressure measured by catheter >16cmH2O | 否/No |
existing pneumothorax or pulmonary bulla Without drainage. | 否/No |
the dispensability index of the inferior vena cava, dIVC | 20.34% |
Stroke VolumeVariation, SVV | 18.72 |
IVCdmax | 1.62 |
Mean airway pressure | 4.9 |
peak inspiratory pressure | 14 |
cardiac output | 4.34 |
CVP | 5 |
Pulse Pressure Variation, PPV | 17.82 |
peak inspiratory pressure | PEEP=0时,14;PEEP=5时,17;PEEP=10时,24;PEEP=15时,28. |
Mean airway pressure | PEEP=0时,4.9;PEEP=5时,4.9;PEEP=10时,8.8;PEEP=15时,12. |
IVCdmax | PEEP=0时,1.62;PEEP=5时,1.78;PEEP=10时,1.88;PEEP=15时,1.96. |
CVP | PEEP=0时,5;PEEP=5时,5;PEEP=10时,9;PEEP=15时,12. |
the dispensability index of the inferior vena cava, dIVC | PEEP=0时,20.34%;PEEP=5时,21.74%;PEEP=10时,16.28%;PEEP=15时,16%. |
Pulse Pressure Variation | PEEP=0时,17.78;PEEP=5时,24.32;PEEP=10时,23.38;PEEP=15时,24.73. |
Stroke VolumeVariation, SVV | PEEP=0时,18.66;PEEP=5时,18.3;PEEP=10时,22.75;PEEP=15时,26.17. |
cardiac output | PEEP=0时,5.14;PEEP=5时,4.95;PEEP=10时,4.83;PEEP=15时,4.38. |