Patients had invasive mechanical ventilation; vasoactive agent wasn’t used or had been evacuate | 是/Yes |
sinus rhythm | 是/Yes |
existing fluid infusion test contraindication (acute coronary syndrome, cardiogenic shock and evidence showing overload fluid) | 否/No |
being obvious right ventricular dysfunction, right heart failure and tricuspid regurgitation | 否/No |
being younger than 18 years old | 否/No |
being gestation | 否/No |
being intra-abdominal hypertension, bladder pressure measured by catheter >16cmH2O | 否/No |
existing pneumothorax or pulmonary bulla Without drainage. | 否/No |
the dispensability index of the inferior vena cava, dIVC | 7.62% |
Stroke VolumeVariation, SVV | 7.6 |
IVCdmax | 2.02 |
Mean airway pressure | 5.5 |
peak inspiratory pressure | 12 |
cardiac output | 5.32 |
CVP | 8 |
Pulse Pressure Variation, PPV | 7.82 |
peak inspiratory pressure | PEEP=0时,14;PEEP=5时,19;PEEP=10时,24;PEEP=15时,29. |
Mean airway pressure | PEEP=0时,5.7;PEEP=5时,10;PEEP=10时,16;PEEP=15时,17. |
IVCdmax | PEEP=0时,2.06;PEEP=5时,2.1;PEEP=10时,2.2;PEEP=15时,2.27. |
CVP | PEEP=0时,10;PEEP=5时,11;PEEP=10时,12;PEEP=15时,16. |
the dispensability index of the inferior vena cava, dIVC | PEEP=0时,7.59%;PEEP=5时,4.38%;PEEP=10时,11.54%;PEEP=15时,9.38%. |
Pulse Pressure Variation | PEEP=0时,7.78;PEEP=5时,9.18;PEEP=10时,12.3;PEEP=15时,14.18. |
Stroke VolumeVariation, SVV | PEEP=0时,7.6;PEEP=5时,9.32;PEEP=10时,11.46;PEEP=15时,13.19. |
cardiac output | PEEP=0时,6.2;PEEP=5时,6;PEEP=10时,5.78;PEEP=15时,5.17. |