Patients had invasive mechanical ventilation; vasoactive agent wasn’t used or had been evacuate | 是/Yes |
sinus rhythm | 是/Yes |
existing fluid infusion test contraindication (acute coronary syndrome, cardiogenic shock and evidence showing overload fluid) | 否/No |
being obvious right ventricular dysfunction, right heart failure and tricuspid regurgitation | 否/No |
being younger than 18 years old | 否/No |
being gestation | 否/No |
being intra-abdominal hypertension, bladder pressure measured by catheter >16cmH2O | 否/No |
existing pneumothorax or pulmonary bulla Without drainage. | 否/No |
the dispensability index of the inferior vena cava, dIVC | 11.13% |
Stroke VolumeVariation, SVV | 1.38 |
IVCdmax | 2.12 |
Mean airway pressure | 5.5 |
peak inspiratory pressure | 10 |
cardiac output | 5.39 |
CVP | 7 |
Pulse Pressure Variation, PPV | 9.66 |
peak inspiratory pressure | PEEP=0时,10;PEEP=5时,18;PEEP=10时,22;PEEP=15时,28. |
Mean airway pressure | PEEP=0时,5.5;PEEP=5时,8.8;PEEP=10时,15;PEEP=15时,17. |
IVCdmax | PEEP=0时,2.12;PEEP=5时,1.91;PEEP=10时,2.02;PEEP=15时,2.01. |
CVP | PEEP=0时,7;PEEP=5时,10;PEEP=10时,11;PEEP=15时,14. |
the dispensability index of the inferior vena cava, dIVC | PEEP=0时,11.13%;PEEP=5时,8.74%;PEEP=10时,10.91%;PEEP=15时,12.14%. |
Pulse Pressure Variation | PEEP=0时,9.66;PEEP=5时,12.23;PEEP=10时,13.14;PEEP=15时,12.27. |
Stroke VolumeVariation, SVV | PEEP=0时,1.38;PEEP=5时,12.2;PEEP=10时,14.25;PEEP=15时,15.73. |
cardiac output | PEEP=0时,6.3;PEEP=5时,6.32;PEEP=10时,6.11;PEEP=15时,.5.68 |