Patients had invasive mechanical ventilation; vasoactive agent wasn’t used or had been evacuate | 是/Yes |
sinus rhythm | 是/Yes |
existing fluid infusion test contraindication (acute coronary syndrome, cardiogenic shock and evidence showing overload fluid) | 否/No |
being obvious right ventricular dysfunction, right heart failure and tricuspid regurgitation | 否/No |
being younger than 18 years old | 否/No |
being gestation | 否/No |
being intra-abdominal hypertension, bladder pressure measured by catheter >16cmH2O | 否/No |
existing pneumothorax or pulmonary bulla Without drainage. | 否/No |
the dispensability index of the inferior vena cava, dIVC | 12.3% |
Stroke VolumeVariation, SVV | 9.8 |
IVCdmax | 1.64 |
Mean airway pressure | 5 |
peak inspiratory pressure | 10 |
cardiac output | 4.87 |
CVP | 4 |
Pulse Pressure Variation, PPV | 25.31 |
peak inspiratory pressure | PEEP=0时,10;PEEP=5时,17;PEEP=10时,23;PEEP=15时,29. |
Mean airway pressure | PEEP=0时,5;PEEP=5时,8;PEEP=10时,15;PEEP=15时,17. |
IVCdmax | PEEP=0时,1.64;PEEP=5时,1.58;PEEP=10时,1.7;PEEP=15时,1.68. |
CVP | PEEP=0时,4,;PEEP=5时,7;PEEP=10时,8;PEEP=15时,12. |
the dispensability index of the inferior vena cava, dIVC | PEEP=0时,12.3%;PEEP=5时,12.8%;PEEP=10时,10.6%;PEEP=15时,9.8%. |
Pulse Pressure Variation | PEEP=0时,25.19;PEEP=5时,22.95;PEEP=10时,33.63;PEEP=15时,44.92. |
Stroke VolumeVariation, SVV | PEEP=0时,9.78;PEEP=5时,10.4;PEEP=10时,10.6;PEEP=15时,10.17. |
cardiac output | PEEP=0时,5.75;PEEP=5时,4.08;PEEP=10时,4.76;PEEP=15时,4.26. |