Patients had invasive mechanical ventilation; vasoactive agent wasn’t used or had been evacuate | 是/Yes |
|
sinus rhythm | 是/Yes |
|
existing fluid infusion test contraindication (acute coronary syndrome, cardiogenic shock and evidence showing overload fluid) | 否/No |
|
being obvious right ventricular dysfunction, right heart failure and tricuspid regurgitation | 否/No |
|
being younger than 18 years old | 否/No |
|
being gestation | 否/No |
|
being intra-abdominal hypertension, bladder pressure measured by catheter >16cmH2O | 否/No |
|
existing pneumothorax or pulmonary bulla Without drainage. | 否/No |
|
the dispensability index of the inferior vena cava, dIVC | 2.88% |
|
Stroke VolumeVariation, SVV | 6.78 |
|
IVCdmax | 2.09 |
|
Mean airway pressure | 5 |
|
peak inspiratory pressure | 12 |
|
cardiac output | 4.59 |
|
CVP | 9 |
|
Pulse Pressure Variation, PPV | 5.98 |
|
peak inspiratory pressure | PEEP=0时,13;PEEP=5时,17;PEEP=10时,22;PEEP=15时,27. |
|
Mean airway pressure | PEEP=0时,5.1;PEEP=5时,9.5;PEEP=10时,15;PEEP=15时,20. |
|
IVCdmax | PEEP=0时,2.14;PEEP=5时,2.14;PEEP=10时,1.89;PEEP=15时,2.11. |
|
CVP | PEEP=0时,10;PEEP=5时,12;PEEP=10时,13;PEEP=15时,16. |
|
the dispensability index of the inferior vena cava, dIVC | PEEP=0时,2.84%;PEEP=5时,3.29%;PEEP=10时,7.21%;PEEP=15时,7.12%. |
|
Pulse Pressure Variation | PEEP=0时,5.98;PEEP=5时,8.12;PEEP=10时,8.35;PEEP=15时,8.38. |
|
Stroke VolumeVariation, SVV | PEEP=0时,6.75;PEEP=5时,7.33;PEEP=10时,6.67;PEEP=15时,7.18. |
|
cardiac output | PEEP=0时,5.28;PEEP=5时,5;PEEP=10时,4.85;PEEP=15时,4.37. |