Patients had invasive mechanical ventilation; vasoactive agent wasn’t used or had been evacuate | 是/Yes |
sinus rhythm | 是/Yes |
existing fluid infusion test contraindication (acute coronary syndrome, cardiogenic shock and evidence showing overload fluid) | 否/No |
being obvious right ventricular dysfunction, right heart failure and tricuspid regurgitation | 否/No |
being younger than 18 years old | 否/No |
being gestation | 否/No |
being intra-abdominal hypertension, bladder pressure measured by catheter >16cmH2O | 否/No |
existing pneumothorax or pulmonary bulla Without drainage. | 否/No |
the dispensability index of the inferior vena cava, dIVC | 9.79% |
Stroke VolumeVariation, SVV | 7.58 |
IVCdmax | 2.13 |
Mean airway pressure | 5 |
peak inspiratory pressure | 11 |
cardiac output | 5.02 |
CVP | 8 |
Pulse Pressure Variation, PPV | 11.45 |
peak inspiratory pressure | PEEP=0时,11;PEEP=5时,18;PEEP=10时,22;PEEP=15时,28. |
Mean airway pressure | PEEP=0时,5;PEEP=5时,9.5;PEEP=10时,14;PEEP=15时,21. |
IVCdmax | PEEP=0时,2.17;PEEP=5时,2.09;PEEP=10时,2.14;PEEP=15时,2.12. |
CVP | PEEP=0时,8;PEEP=5时,9;PEEP=10时,12;PEEP=15时,15. |
the dispensability index of the inferior vena cava, dIVC | PEEP=0时,9.76%;PEEP=5时,7.88%;PEEP=10时,6.02%;PEEP=15时,6.17%. |
Pulse Pressure Variation | PEEP=0时,11.33;PEEP=5时,12.38;PEEP=10时,14.38;PEEP=15时,16.88. |
Stroke VolumeVariation, SVV | PEEP=0时,7.52;PEEP=5时,7.48;PEEP=10时,8.08;PEEP=15时,3.12. |
cardiac output | PEEP=0时,5.85;PEEP=5时,5.76;PEEP=10时,5.186PEEP=15时,4.96. |