Patients had invasive mechanical ventilation; vasoactive agent wasn’t used or had been evacuate | 是/Yes |
sinus rhythm | 是/Yes |
existing fluid infusion test contraindication (acute coronary syndrome, cardiogenic shock and evidence showing overload fluid) | 否/No |
being obvious right ventricular dysfunction, right heart failure and tricuspid regurgitation | 否/No |
being younger than 18 years old | 否/No |
being gestation | 否/No |
being intra-abdominal hypertension, bladder pressure measured by catheter >16cmH2O | 否/No |
existing pneumothorax or pulmonary bulla Without drainage. | 否/No |
the dispensability index of the inferior vena cava, dIVC | 10.36% |
Stroke VolumeVariation, SVV | 7.72 |
IVCdmax | 1.76 |
Mean airway pressure | 5 |
peak inspiratory pressure | 9 |
cardiac output | 4.39 |
CVP | 6 |
Pulse Pressure Variation, PPV | 8.58 |
peak inspiratory pressure | PEEP=0时,9;PEEP=5时,19;PEEP=10时,23;PEEP=15时,28. |
Mean airway pressure | PEEP=0时,5;PEEP=5时,9;PEEP=10时,15;PEEP=15时,19. |
IVCdmax | PEEP=0时,1.76;PEEP=5时,1.98;PEEP=10时,2.12;PEEP=15时,2.2. |
CVP | PEEP=0时,7;PEEP=5时,10;PEEP=10时,11;PEEP=15时,14. |
the dispensability index of the inferior vena cava, dIVC | PEEP=0时,10.36%;PEEP=5时,10.12%;PEEP=10时,8.98%;PEEP=15时,8.17%. |
Pulse Pressure Variation | PEEP=0时,8.43;PEEP=5时,8.93;PEEP=10时,10.34;PEEP=15时,11.49. |
Stroke VolumeVariation, SVV | PEEP=0时,7.67;PEEP=5时,9.3;PEEP=10时,10.17;PEEP=15时,12.34. |
cardiac output | PEEP=0时,5.78;PEEP=5时,5.36;PEEP=10时,5.15;PEEP=15时,5.1. |